Description
SPECIFICATIONS:
Features:
- 12.1" TFT colour LCD, 15-language interface.
- Finish all operations by keys and knobs.
- Be applicable for adult, pediatric and neonatal for all round monitoring.
- Elegant appearance, clear masks, standard interface, oxygen graph, trend graph, big characters, other BED observation, which are convenient for users.
- Sync display of 8-lead ECG.
- Monitoring content, can speed, volume and output contents can be set optionally.
- Waveform and parameters colour can be set optionally.
- Alarm items: Technical alarm, 71 physiological alarms and 60 arrhythmia alarms.
- Adopt digital Sp02 technology, which has strong anti-interference and anti-weak filling capability.
- Trend review for 480-hours, review for 2400 groups of BP data,
- Storage review of 72-hour ECG waveform with the mounting SD card.
- Calculation of drug concentration.
- Network function: Connect central monitoring station, other bed observation and software updating.
- Achieve data storage and software updating by USB interface.
- Connection mode: Wired, WIFI and 3G.
- Built-in rechargeable battery for uninterrupted monitoring.
- Print ECG, Sp02, RESP, BP and TEMP data with one key.
- Anti-high frequency surgical unit, defibrillation, proof (requirement for special leads).
- Analysis function for heart variability (HRV) (optional).
- Standard parameters: ECG, RESP, NIBP, Sp02 and dual channel temp.
- Optional functions: IBP, CO2, built in printer, moving bracket, hanging bracket, VGA output, 12-lead and vehicle power.
- The product has passed FDA certification in America and CE certification in Europe.
NIBP:
- Method: Oscillometric.
- Mode: Manual, Auto, Continual.
- Measurement interval in Auto mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 240, 480, 960 minutes.
- Measuring period in continual mode: 5min.
- Alarm type: SYS, DIA, MEAN.
- Measuring and alarm range:
- Adult mode: SYS: 40-270 mmHg; DIA: 10-215 mmHg; MEAN: 20-235 mmHg.
- Pediatric mode: SYS: 40-200 mmHg; DIA: 10-150 mmHg; MEAN: 20-165 mmHg.
- Neonatal mode: SYS: 40-135 mmHg; DIA: 10-100 mmHg; MEAN: 20-110 mmHg.
- Resolution: Pressure: 1 mmHg.
- Accuracy:
- Pressure
- Mean error: ±5mmHg.
- Maximum Standard deviation: 8mmHg.
- Software overpressure protection
- Adult mode: 297 ±3mmHg.
- Pediatric Mode: 240 ±3mmHg.
- Neonatal Mode: 147 ±3mmHg.
SpO2:
- Measuring Range: 0% - 100%.
- Alarm Range: 0% - 100%
- Resolution: 1%
- Accuracy: 70% - 100% ±2%; 0%-69% unspecified.
- Actualization interval: about 1Sec.
- Alarm Delay: 10Sec.
- Pulse rate:
- Measuring and Alarm range: 30-250bpm.
- Resolution: 1bpm
- Accuracy: ±2bpm
Temp:
- Channel: 2
- Measuring and Alarm range: 0-50 °C.
- Resolution: 0.1°C.
- Accuracy: ±0.1°C.
- Actualization interval: about 1 Sec.
- Average time constant: < 10 sec.
ECG:
- Lead mode: 5 leads (R, L, F, N C or RA, LA, LL, RL, V).
- Lead selection: I, II, III, aVR, aVL, aVF, V.
- Waveform: 2ch.
- Lead mode: 3 Leads (R, L, F or RA, LA, LL).
- Lead selection: I, II, III.
- Waveform: 1 ch.
- Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV.
- HR:
- Measure and Alarm range:
- Adult 15-300bpm.
- Neo/Ped: 15-350 bpm.
- Accuracy: ±1% or ±1bpm, whichever is greater.
- Measure and Alarm range:
- Resolution: 1bpm.
- Sensitivity: >200uV p-p.
- Differential Input Language Impedance: > 5 M Ω.
- Calibration Signal: 1 mV (Vp-p), ±5% Accuracy.
- ST Segment Monitoring Range
- Measurement and Alarm: -2.0-+2.0mV.
- Accuracy: -0.8-+0.8mV, 0.04mV or 10% of which is greater; Other unspecified.
- Tall T - wave rejection capabilitu: 1.2mV.